Osiris-Jaegar – Installer Guide
To edit / create a Position tour
1 Enter the Setup menu, choose Tours and then the required Position Tour number (1 - 16).
2 Choose the Edit/record tour option.
3 Choose the Add option to display the list of available positions (‘@’ indicates a preset position is
programmed).
4 Highlight and select the required preset. See below for details about adjusting speed and dwell time.
5 Repeat steps 3 and 4 until all of the required presets have been added to the tour.
For each preset within the tour you can adjust the positioning speed and dwell time. To edit a specific step in
the tour, highlight the preset number and select it to see the menu below:
Osiris Open Platform
Version n.nnn (xxxx) xx
SN: FFFFFFFF POST: 000000000
Select preset 1
Speed Med
Dwell (secs) 3
Remove preset
Exit menu
Mimic Tours
The ‘@’ suffix indicates that the corresponding tour has been programmed. When you select a tour number,
you will see an options screen for that tour:
To create/replace a Mimic tour.
1 Position the camera to where you wish to start the tour.
2 Enter the Setup menu, choose Tours and then the required Mimic Tour number (M1 – M4).
3 Choose the Edit/record tour option. The tour will start to record immediately, displaying a count-
down of the available time.
4 Pan / Tilt / Zoom the camera as required for the tour pattern.
5 To end and store the recording, select Goto Preset 1 command.
6 To cancel the recording select the Menu function / Goto Preset 2 command.