Osiris-Jaegar – Installer Guide
Configuration
Osiris Open Platform
Version n.nnn (xxxx) xx
SN: FFFFFFFF POST: 000000000
Reverse Tilt Off
Positioning speed 4
Low voltage PSU Off
Pan limit left 0
Pan limit right 0
Tilt limit down 0
Tilt limit up 0
Set North Store
Wash duration 15
Wiper duration 7
Ancillary function Off
Heat Threshhold 0
Ext-pos functions 2
Exit menu
Default values shown. Scroll downwards to view further items.
Reverse Tilt Re-defines Tilt axis for Reverse mounted payloads (Default is Off) – Do Not Change - Factory
use Only.
Positioning speed controls the rate the camera moves under operator control and when moving to preset
positions. This is the peak rate. Slower rates are available through the zoom dependant speed control and
via the settings for the preset positions and tours.
Low voltage PSU allows for smooth motion correction at lower input voltage levels – Applies to some
models only.
Pan limit left and right set limits for the camera travel. The figures are in degrees and the zero point of the
camera needs to be included in the sweep of the travel (although it can be the left or right limit). When these
values are both set to 0 (zero) then the camera travel is unlimited. The new limits will not be changed until
the camera is rebooted.
Tilt limit down and tilt limit up can be used to limit the tilt travel range. The zero point needs to be included
in the range; although it can be the top or bottom limit. The new limits will not be changed until the camera is
rebooted.
Set North – Selects action of Reset command – Applies to certain models only.
Wash duration sets the period for the wash cycle. This is in seconds.
Wiper duration sets the period for the wiper cycle. This is in seconds. Requires external interface device.
Ancillary Function – Selects the action of the Ancilliary circuit. Heater, Cooling fan of White LED lamp.
Applies only to models fitted with Ancillary equipment.
Ext-pos functions sets the base preset number for first of the extended functions that are available as
presets – Menu preset override – The preset value that will open the OSD Menu..
Silent Sentinel SilSen DN145003 - 1.2b (Fork)
8