EasyManuals Logo

Silhouette Alta Plus User Manual

Silhouette Alta Plus
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Silhouette Alta® Plus
Print Head Replacement
Preparation
Silhouette Alta® Plus machine
Preinstalled print head
Replacement print head unit
Tools
#2 Phillips head screwdriver
Remove the preinstalled print head
5. Remove the three (3) Phillips head screws from the top of the
print head. TIP: REMOVE THE SCREWS LEFT TO RIGHT.
6. Remove the cable connectors.
6.1 Pinch the side of the thick connector and pull up.
6.2 Pinch the power cable that connects the fan and pull up.
(DO NOT PULL THE WIRE.)
7. Remove the print head.
4. Remove the hose.
4.1 Push the collar of the connector on the print head down.
4.2 Pull the hose up to remove it.
1. Remove the filament from the print head and wait for the
print head to cool.
2. Remove the Alta platform (also known as the build plate).
3. Using your hand, move the print head flush against the
print bed. Adjust the print head position so that it rests in
the center.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Silhouette Alta Plus and is the answer not in the manual?

Silhouette Alta Plus Specifications

General IconGeneral
Print TechnologyFused Filament Fabrication (FFF)
Filament Diameter1.75 mm
Supported Filament MaterialsPLA
ConnectivityUSB
SoftwareSilhouette 3D
Print Bedremovable

Related product manuals