MAINTENANCE
FOR BEST RESULTS AND LONG-TERM OPERATION REGULAR
MAINTENANCE IS ESSENTIAL.
To ensure the cooler delivers fresh and clean air, regularly change the
water when dirty, and clean both the dust filter and the cooling pad.
1) Remove the filter pad by unscrewing the 4 screws on the rear of
the cooler, then lift the pad and pull out at the bottom to release.
To replace the pad, slide up into the slot under the top of the
cooler, push in at the bottom and allow to drop into the lower
slot.
2) Clean the pad from the inner-side to out-side of pad (inner side is
towards motor). Never use any liquid detergent. Never use
pressurized water, as it may cause damage to the pad.
3) Unscrew the drainage lid to let dirty water flow out, then clean
the water tank thoroughly with a soft cloth. Wash off dirt on the
water sensor, water pump and the float valve. Rinse thoroughly.
4) Use mild soap and soft clean cloth when cleaning the cooler casing.
Do not use any caustic chemical detergent that may cause damage
to the surface of the cooler.
5)To prevent build-up of algae and biological organisms in the
reservoir, regularly add chlorine/bromine tablets as per tablet
manufacturer recommendation for evaporative cooler reservoirs.
SPARE PARTS: