61 GB/MT
operation. Also instruct other
users of the hazards!
Please note that some of the
product‘s parts may still be hot
even after it has been switched off.
Do not insert hands, fingers or
objects into the air inlets
5
,
9
or air outlets
3
,
7
. Make chil-
dren in particular aware of this
hazard.
Always transport and store the
product upright, never at an angle.
Switch off the product and unp
lug
the mains plug
10
from the socket
before moving the product.
Do not use the product in rooms
where flammable gases may be
present.
Keep long hair away from the
product. It could get sucked into
the air inlets
5
,
9
.
Avoid using spray cans near the
product.
Operate and store the product
in a room with a floor space of
at least 4 m².
For safety reasons, do not leave
the house if the windows are
open to let hot air out of the
product.
DANGER DUE TO
REFRIGERANT!
The product contains 140 g of
refrigerant gas R290, which is
highly flammable and can cause
damage to health and the
environ-
ment if not handled properly.
Note that refrigerants can be
odourless.
Avoid contact with the refrigerant
and never damage the refriger-
ant circuit.
Only store the product in rooms
without continuously operating
ignition sources (e.g. open fla
mes,
active gas appliances, active
electric heaters, etc.).
Operate the product only in suf-
ficiently ventilated rooms with a
floor space of at least 4 m².
The area in which the product
is located must be designed in
such a way that any refrigerant
gas that may escape cannot
accumulate.
Store the product in such a way
as to avoid mechanical damage.
Repairs and maintenance work
on the refrigerant circuit may o
nly
be carried out by specialist per-
sonnel certified for this purpose.