SIMARINE PICO/PICOone Battery Monitoring System
Mount types: STANDALONE and PANEL-MOUNT
Congratulations on your purchase of the SIMARINE PICO Smart Battery Monitoring system.
PICO is used to monitor DC power sources (e.g. batteries, solar panels, wind turbines),
consumers (e.g. refrigerators, lights, equipment), tank levels and temperatures. The
information is displayed on a high brightness, sunlight readable 3,5” IPS display with Gorilla®
Glass protection and anti-reflective coating to ensure superb visibility.
1 What’s in the box
1 x PICO
1 x DOUBLE SIDED TAPE (Standalone only)
1 x WARRANTY
4 x M3 THREADED ROD
1 x QUICK GUIDE
4 x M3 NUT
1 x INSTALLATION TEMPLATE
2 x BRACKET (Panel-mount only)
1 x SPLITTER WITH CABLE
2 Accessories
SC302T Digital Shunt SIMARINE High Precision 300A Shunt with 2 resistance inputs for
tank level measurement and 2 voltage inputs for measuring voltages of two batteries
SC500 Digital Shunt SIMARINE High Precision 500A Shunt
SCQ25 Quadro Digital Shunt Module SIMARINE High Precision 4x25A Shunt
SCQ25T Quadro Digital Shunt and Tank Module SIMARINE High Precision 4x25A Shunt
and Tank Module with 7 inputs
ST107 Digital tank module with 7 Inputs
3 Safety
Installation of SIMARINE electronics should be made by electrical specialists with proper
safety equipment. When working with batteries you should wear protective clothing and
eye protection.
CAUTION: Batteries contain acid, a corrosive, colorless liquid that can harm your eyes, skin
and damage clothing. Should the acid come in contact with eyes, skin or clothing, wash it
immediately with soap under fresh water for at least 15 minutes, and seek medical support
immediately.
CAUTION: Do NOT connect anything to a damaged battery. It could heat up, catch fire or
explode.
CAUTION: Lead-acid Batteries can generate explosive gases during operation. Never
smoke, allow flames or sparks near the battery. Make sure to keep sufficient ventilation
around the battery.
CAUTION: When working with a battery remove all personal metal items like watches, rings,
necklaces and bracelets. Metal items in contact with the battery terminals might cause a
short circuit with a very high electric current, which may heat up and melt nearby objects
and cause severe burns.
4 Declaration of conformity
MANUFACTURER:
SIMARINE d.o.o.
ADDRESS:
Ulica skofa Maksimilijana Drzecnika 6,
SI-2000 Maribor, Slovenia, EU
Declares that the following product:
PRODUCT TYPE:
PICO
Conforms to the requirements of the following Directives of the European Union:
EMC Directive 2014/30EU, RoHS Directive 2002/95/EC
The above product is in conformity with the following harmonized standards:
EN61000-6-3: 2001 EMC - Generic Emissions Standard, EN61000-6-2: 2005 EMC - Generic
Immunity Standard
5 Installation
5.1 PICO mounting
SIMARINE PICO should be installed in a visible place to provide good readability. Please
note that ONLY the PICO/PICOone display unit is water and dust resistant! Any other
modules including splitter should not be exposed to humidity or liquids in any case. The
mounting process and installation cutouts depend on the model, as described in following
sections.
5.2 PICO STANDALONE
PICO Standalone version has dimensions of 98 x 84 x 10mm (3.85 x 3.30 x 0.39 in) and needs
NO installation cutout. The mounting process requires drilling of 5 (PICOone) or 6 (PICO)
mounting holes and access to the rear of the mounting surface. In case you have NO rear
access, you can bond it using supplied double sided tape.
Step to be taken for proper mounting:
1. Before the drilling, check if there is enough space to mount your PICO.
2. Mark mounting holes using the supplied installation template.
3. Drill all holes.
4. Connect the connector on the back side of PICO to the splitter cable (be sure to
align the pins correctly) and fasten it by turning the safety ring clockwise.
5. Finish mounting PICO from the back side with the supplied threaded rod and nuts.
Screws, rods and nuts MUST be screwed by hand. Excessive force may damage
the threads on PICO.
5.3 PICO PANEL-MOUNT
PICO Panel-mount version dimensions are 108.5 x 94 x 10mm. It needs an installation cutout
of 98 x 83mm. It can be mounted with supplied threaded rods and brackets or bonded with
adhesive if there is no rear access to the mounting surface.
Steps to be taken for proper mounting:
1. Before cutting out, check if there is enough space for your PICO.
2. Mark the cutout line with the supplied installation template.
3. Using a saw, carefully cut out the marked area.
4. Connect the connector on the back side of PICO to the splitter cable (be sure to
align the pins correctly) and fasten it by turning the safety ring clockwise.
5. Finish mounting PICO from the back side with the supplied threaded rod and nuts.
Screws, rods and nuts MUST be screwed by hand. Excessive force may damage
the threads on PICO.

Other manuals for SIMARINE PICO

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIMARINE PICO and is the answer not in the manual?

SIMARINE PICO Specifications

General IconGeneral
ConnectivityWi-Fi, Bluetooth
Power Supply12-24V DC
Water ResistanceIP67
Dimensions83 x 76 x 10 mm
Flush Mount Depth8 mm
DisplayLCD
Operating Temperature-20°C to 70°C