EasyManua.ls Logo

Sime BRAVA SLIM 30 BFR - User Manual

Sime BRAVA SLIM 30 BFR
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Fonderie SIME S.p.A.
6321734 - 01/2024 - R0
Cod.
USER MANUAL
TO BE LEFT WITH THE OCCUPANT
BRAVA SLIM 30 BFR
Gas Safety Certified AS/NZS 5263.1.2
LN: SAI-400197
CAUTION
This product must be installed exclusively by professional-
ly qualified personnel in accordance with the requirements
of the standards AS/NZS 5601, AS/NZS 3500, AS/NZS 3000
(current version) of the local gas, electricity authorities and
other relevant legislation.
Low temperature wall mounted boiler
EN
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
To consult the documentation,
visit our website www.sime.it

Other manuals for Sime BRAVA SLIM 30 BFR

Question and Answer IconNeed help?

Do you have a question about the Sime BRAVA SLIM 30 BFR and is the answer not in the manual?

Summary

Using the Boiler

Control Panel Overview

Detailed explanation of the boiler's control panel, buttons, and display indicators for operation.

Preliminary Checks Before Operation

Essential checks to perform before starting the boiler, including system pressure and valve status.

Boiler Ignition Procedure

Step-by-step guide on how to start the boiler, including setting the mode and checking pressure.

Adjusting Heating Temperature

Instructions on how to increase or decrease the desired heating temperature set point.

Fault and Malfunction Codes

Information on identifying and responding to fault codes displayed on the boiler's control panel.

Boiler Shutdown Procedures

Temporary Shutdown

How to temporarily stop the boiler operation, including standby mode and display indications.

Long-Term Shutdown

Procedure for leaving the boiler unused for extended periods, including safety precautions.

Boiler Maintenance

Scheduled Maintenance Adjustments

Recommendation for biannual maintenance by a qualified technician for optimal operation.

External Cleaning

Instructions for cleaning the boiler's external casing using appropriate materials.

Equipment Disposal

Disposal of Electrical and Electronic Waste

Guidelines for disposing of the appliance as WEEE waste in compliance with European directives.

Installation and Service Records

Installer Details Record

Section to record installer's company, contact, and certification information for the installation.

System Details Record

Section to record the boiler model, serial number, and installation address.

Customer Care and Service Programme

Emphasis on service and maintenance for prolonged useful life and maximum efficiency.

Handover Instructions to User

User Operation and System Handover

Instructions for the installer to guide the end user on boiler operation, maintenance, and system features.

Service Records

Service Record Entries

Fields to log service technician details, company, contact, and work completed for annual servicing.

Summary

Using the Boiler

Control Panel Overview

Detailed explanation of the boiler's control panel, buttons, and display indicators for operation.

Preliminary Checks Before Operation

Essential checks to perform before starting the boiler, including system pressure and valve status.

Boiler Ignition Procedure

Step-by-step guide on how to start the boiler, including setting the mode and checking pressure.

Adjusting Heating Temperature

Instructions on how to increase or decrease the desired heating temperature set point.

Fault and Malfunction Codes

Information on identifying and responding to fault codes displayed on the boiler's control panel.

Boiler Shutdown Procedures

Temporary Shutdown

How to temporarily stop the boiler operation, including standby mode and display indications.

Long-Term Shutdown

Procedure for leaving the boiler unused for extended periods, including safety precautions.

Boiler Maintenance

Scheduled Maintenance Adjustments

Recommendation for biannual maintenance by a qualified technician for optimal operation.

External Cleaning

Instructions for cleaning the boiler's external casing using appropriate materials.

Equipment Disposal

Disposal of Electrical and Electronic Waste

Guidelines for disposing of the appliance as WEEE waste in compliance with European directives.

Installation and Service Records

Installer Details Record

Section to record installer's company, contact, and certification information for the installation.

System Details Record

Section to record the boiler model, serial number, and installation address.

Customer Care and Service Programme

Emphasis on service and maintenance for prolonged useful life and maximum efficiency.

Handover Instructions to User

User Operation and System Handover

Instructions for the installer to guide the end user on boiler operation, maintenance, and system features.

Service Records

Service Record Entries

Fields to log service technician details, company, contact, and work completed for annual servicing.

Overview

The Sime Brava Slim 30 BFR is a low-temperature, wall-mounted boiler designed for heating purposes. This user manual provides essential information for its safe and efficient operation, maintenance, and installation. It is intended to be kept by the occupant for future reference.

Function Description

The Brava Slim 30 BFR boiler is a latest-generation modulating appliance that provides heating with maximum safety and low running costs. It operates in various modes, including "Stand-by," "Summer" (though not applicable to this specific boiler model), and "Winter." The boiler's control panel allows users to monitor its status, adjust settings, and identify any faults or malfunctions.

Key operational features include:

  • Operating Modes: Users can cycle through "Stand-by" and "Winter" modes using the main system switch. The "Summer" mode symbol may appear but is not functional for this model.
  • Temperature Adjustment: The heating flow temperature can be set between 20 and 80°C using the control panel buttons.
  • Pressure Monitoring: The display shows the heating system pressure, which should ideally be between 1-1.2 bar (100-120 kPa) when cold. If the pressure is too low (alarm "02"), users are instructed to open the filling valve to increase it.
  • Fault Indication: In case of a fault, an "ALL" message will appear on the display, followed by a specific fault code (e.g., "06" for no flame, "07" for safety thermostat intervention, "02" for low water pressure).
  • Antifreeze Function: The boiler is equipped with a standard antifreeze function and an anti-freeze kit to -15°C, allowing it to be installed in partially covered areas with ambient temperatures between -5°C and 60°C.
  • Power Level Indicator: The display shows the power level at which the boiler is operating.
  • Maintenance Request Indicator: A symbol will appear to indicate when it's time for maintenance.

Usage Features

The boiler is designed for user-friendly operation, though installation and major maintenance require professional intervention.

  • Ignition: After ensuring gas and water valves are open and preliminary checks are complete, users can start the boiler by setting the main system switch to "ON" and selecting the "Winter" operating mode.
  • Temperature Control: The heating temperature can be easily adjusted using the dedicated buttons on the control panel.
  • Troubleshooting: The manual provides instructions for addressing common alarms like low water pressure ("02"), no flame ("06"), and safety thermostat intervention ("07"). Users are guided to reset the boiler by pressing the main system switch button for at least 3 seconds after resolving the issue.
  • Temporary Shutdown: For short periods of non-use, the boiler can be put into "Stand-by" mode by pressing and holding the main system switch button. In this mode, the boiler remains powered, and the gas valve should be left open, especially if outside temperatures might fall below zero, to allow the antifreeze function to operate.
  • Long-Term Shutdown: For extended periods of non-use, the boiler should be put into "Stand-by" mode, the main system switch set to "OFF," and both the gas and heating system isolation valves closed. Draining the heating system is recommended if there's a risk of freezing.
  • Safety Precautions: The manual emphasizes several prohibitions, such as not allowing children or unassisted disabled persons to use the appliance, not touching it with wet hands or feet, and not modifying safety devices. It also warns against installing the boiler in environments that may limit its optimum operation (e.g., marine environments) or near flammable substances.

Maintenance Features

Regular maintenance is crucial for the boiler's correct and efficient operation, as well as for ensuring its prolonged useful life.

  • Recommended Maintenance: Sime recommends that maintenance and checks be carried out twice a year by a professionally qualified technician.
  • BI-ANNUAL Maintenance: The user is advised to call upon the services of a Professionally Qualified Technician for BI-ANNUAL maintenance.
  • External Cleaning: The cladding can be cleaned with a cloth dampened with soap and water or alcohol for stubborn marks. Abrasive products are forbidden.
  • Professional Intervention: All maintenance interventions, adjustments, and repairs must be carried out solely by professionally qualified personnel using original spare parts. Failure to comply with these instructions can jeopardize the appliance's safety and void the warranty.
  • Accessing Components: When accessing the bottom part of the appliance for maintenance, users are warned to ensure system components and pipes are not hot and to wear protective gloves.
  • Service Records: The manual includes dedicated sections for service records, allowing technicians to document maintenance performed over the years (Year 1, Year 3, Year 5, Year 7, Year 9, Year 11, Year 13). This helps track the boiler's service history.
  • Handover Instructions: The manual provides a checklist for installers to ensure the end-user is properly instructed on how to operate the system, perform basic fault resolution, and understand the importance of regular servicing. It specifically recommends that the boiler be serviced at/before the start of winter every year and that the heat exchanger be flushed at every service.
  • Disposal: At the end of its life span, the appliance must be disposed of in accordance with the European Directive 2012/19/EU, treating it as electrical and electronic waste. Disposal with urban waste is forbidden.

Sime BRAVA SLIM 30 BFR Specifications

General IconGeneral
Gas TypeNatural Gas
Fuel TypeGas
Output30 kW
Dimensions (HxWxD)700 x 400 x 250 mm
IgnitionElectronic
Heat Exchanger MaterialStainless Steel
Warranty2 Years
MountingWall-mounted
Central Heating Output (kW)30 kW