14
TechnicalParameters
Model
ECOMAXI VB 200ECOMAXI VB 200 S
Operational mode
Heat pump, Automatic and Boost mode
Power supply
220-240V~ 50Hz
Max. power input (under boost mode)
2400W
Max. current input (under boost mode)
10.43A
Heat pump
Max. power input
900W
Heating up time
5:24(h:min)
Refrigerant
R134a/600g
Declared load profile
L
COPDHW
2,797
(1)
3,331
(2)
Mixed water at 40
243,7L
(1)
247,1L
(2)
Energy efficiency
117,7%
(1)
139,6%
(2)
Energy efficiency class
A+
(1)
A+
(2)
Annual electrical consumption
870kWh
(1)
733kWh
(2)
Max. outlet water temp.
65 (default 52)
Operating temp. range
-7℃~43
Electric
heating
Rated power input
1500W
Max. outlet water temp.
75
Max. operating pressure for refrigerant
circuit (discharge side/suction side)
2.4MPa/0.6MPa
Storage
tank
Rated capacity
200L
Max. operating Pressure
1.0MPa
Water inlet/outlet
DN20
Solar energy inlet/outlet
DN20
Anti-electric shock class
Class Ι
Sound power level
(3)
58dB (A)
Net weight(kg)
100
110
Dimensions(mm)
φ662*1530
Note (1): Performance conditionambient air 7°C DB/ 6°C WB, incoming/final water temperature 1C /
52°C, according to EN 16147:2017, (EU) NO 814-2013.
Note (2): Performance conditionambient air 14°C DB/ 13°C WB, incoming/final water temperature
10°C / 52°C, according to EN 16147:2017, (EU) NO 814-2013.
Note (3): Sound power level tested with air duct, according to EN 12102-1-2017, ISO 3744:2010.