SRM9000 ALIGNMENT TNM-M-E-0019 Issue 1
Page 10 of 13
RSSI
1.
Select the RSSI Cal page.
2. Set the Signal Generator for a RF output level of -90dBm and 2kHz deviation at the specified
frequency.
3.
Activate the Store RSSI button.
The receiver RSSI threshold setting is calibrated.