EasyManua.ls Logo

Simon 3 - Option 12: Phone Mod 1; Option 13: Phone Mod 2; Option 14: DTMF Dialing; Option 15: no Activity Time-Out

Simon 3
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Programming
If a delay door is opened after the Exit Delay expires, the Entry
Delay begins. If the user arms the system with No Delay and
opens a delay door after the Exit Delay expires, an alarm
occurs.
When turned on, the Exit Delay can be set from 005-254 sec-
onds (045-254 if SIA Limits Option 69 is on). All entries must
be 3 digits. When turned off, the Exit Delay is set to 005 sec-
onds (045 if Option 69: SIA Limits is on).
Note
For UL listed systems, the exit delay must not exceed 60
seconds.
To set Exit Delay, press:
AddOption #113-digit delay timeDONE.
To reset Exit Delay (return to default), press:
DeleteOption #11DONE.
Option 12: Phone Mod 1 (Default = 0)
Determines the primary phone number (Option 4) report con-
tent and reporting format.
Note
UL has only verified reporting compatibility with the ITI
CS5000 Digital Alarm Communicator Receiver. For UL
listed systems, Phone Mod 1 must be set to 0 or 1.
The following table describes the choices.
Alarms include: Fire, Intrusion, Emergency, Silent, and Alarm
Cancels.
Non-alarms include: Latchkey, No Activity, Openings, Clos-
ings, Fail to Open, Fail to Close, Force Armed, AC Power Fail-
ure, CPU Low Battery, and Trouble Restorals.
To set Phone Mod 1, press:
AddOption #120, 1, 2, or 3DONE.
To reset Phone Mod 1 (return to default), press:
DeleteOption #12DONE.
Option 13: Phone Mod 2 (Default = 00)
Determines the secondary phone number (Option 5) report
content and reporting format. The following table describes the
choices. All entries must be 2 digits.
To set Phone Mod 2, press:
AddOption #130, 1, 2, or 3DONE.
To reset Phone Mod 2 (return to default), press:
DeleteOption #13DONE.
Option 14: DTMF Dialing (Default = on)
Determines whether the panel uses DTMF (on) or pulse (off)
for dialing programmed phone numbers.
To turn on DTMF Dialing, press:
AddOption #14DONE.
To turn off DTMF Dialing, press:
DeleteOption #14DONE.
Option 15: No Activity Time-out (Default = off)
Determines whether the panel sends a No Activity report to a
central station or pager when the programmed time period
elapses (on), or if the feature is disabled (off).
No activity means control panel, remote handheld, and key-
chain touchpad buttons have not be pressed and sensors have
not been tripped within a specified period of time (except sen-
sors in group 25).
The time-out can be set from 02 - 24 hours. All entries must be
2 digits.
Phone Mod 1
Setting # Content Format
0All SIA
1 All Contact ID
2 Alarms only SIA
3 Alarms only Contact ID
Phone Mod 2
Setting # Content Format
00 All SIA
01 All Contact ID
02 Alarms only SIA
03 Alarms only Contact ID
04 Non-Alarms only SIA
05 Non-Alarms only Contact ID
06 Phone 1 failure SIA
07 Phone 1 failure Contact ID
08 Latchkey, No Activity, Phone Test,
Openings, Closings, Fail to Open/
Close, AC Power Restorals/
Failures
Pager
09 Same as setting 8 plus Alarms Pager
10 Alarms only (See Options 43 and
44 for more details.)
Voice Event
Notification

Table of Contents