Simonelli MICROBAR - Machine Block Alarm Messages; Upper Piston Motor Group Alarm; Heater Filling Alarm; Turbine Alarm

Default Icon
192 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use the Hot
Water key to
eliminate any
air bubbles.
Fill the water tank.The coffee will
not be deliv-
ered and the
dosing will be
halted while in
progress.
The water tank
is empty.
WATER TANK EMPTY ALARM
DISPLAY CAUSA EFFECT SOLUTION NOTE
The volume
counter has
reached the
number of litres
of deliverable
water set during
pr ogr ammin g
phase.
Coffee will not
be delivered;
the dose will not
be halted or it is
variable.
Regenerate clean-
ing filter salts. To
erase the alarm
see paragraph
on ‘RESETTING
C L E A N I N G
FILTER LITRE
COUNTER’.
This alarm
will not halt
delivery. The
cleaning filter
alarm can be
eliminated by
programming
the number
of litres to
zero (see
paragraph on
PROGRAM-
MING’).
CLEANING FILTER
ALARM
One of the two
t e m p e r a t u r e
probes is bro-
ken.
Coffee will not
be delivered.
Substitute the bro-
ken probe.
This alarm
blocks all
deliveries.
TEMPERATURE PROBE
MALFUNCTION ALARM
Too much cof-
fee.
Coffee will not
be delivered and
an ejection cycle
will be effected.
Reduce the quan-
tity of coffee.
COFFEE QUANTITY
ALARM
68
UK