9
Press and hold both the MENU and MODE buttons for 5 seconds to enter the
Advanced Menu.
Press DOWN until >HVAC is shown.
Press MODE to enter the HVAC conguration menu.
The following settings are available:
HVAC TYPE HEAT COOL
HEAT ONLY
COOL ONLY
HT PUMP
HT PUMP EMR
Type of system connected to this
thermostat.
This setting is read-only when Wi-Fi is
congured.
CHANGEOVER O – COOL ON
B – HEAT ON
Applies only to heat pumps.
Determines whether heat or cool is
active. Most heat pumps are O, but
Rheem/Ruud typically use B.
If your heat pump is heating when
it should be cooling, and vice-versa,
please change this setting.
FURNACE GAS
ELECTRIC
Applies only to forced air systems,
including heat pump emergency heat.
Step 2: Enter System Conguration