5 S4100-0103 5/2013
Audio Riser Modules
Model Description Size Supv. Alarm
4100-0621
Dual Channel Analog Audio Riser Module; accepts one or two separate audio signals from
host control panel; mounts in Block B, is controlled by Transponder Interface Module
1 Block 0 mA 15 mA
4100-0622
3-8 Channel Digital Audio Riser Module; similar to analog module, except receives and
decodes a digital input signal with up to eight audio channels; with Non-Alarm Audio input
1 Block 70 mA 70 mA
Analog Emergency Voice/Alarm Communications Equipment, Constant Supervision Compatible*
Model Description Details
4100-1361 25 VRMS output
Flex-35, 35 W Amplifier, constant
supervision compatible
Includes three on-board
Class B audio NACs;
power is supplied from
an EPS+, EPS, or XPS
NAC rating = 1.4 A
35 W, or 100
speakers
4100-1362 70.07 VRMS output NAC rating = 0.5 A
4100-1312 25 VRMS output
Flex-50, 50 W Amplifier, constant
supervision compatible
NAC rating = 2 A
50 W, or 100
speakers
4100-1313 70.7 VRMS output NAC rating = 0.707 A
100 W Analog Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing Description Details
25 VRMS 70.7 VRMS
4100-1314 4100-1315 120 VAC, 60 Hz UL
Primary
100 W
Amplifier
Includes six, Class B audio NACs;
NAC rating = 50 W or 100 speakers
maximum; 2 A @ 25 VRMS;
1.4 A @ 70.7 VRMS
ULC
models
have low
battery
dropout
circuit
4100-1316 4100-1317 120 VAC, 60 Hz ULC
4100-1318 4100-1319 220/230/240 VAC, 50/60 Hz UL
4100-1320
4100-1321
120 VAC, 60 Hz UL
Backup
100 W
Amplifier
Uses the six Class B NACs of primary
amplifier
4100-1322
4100-1323
120 VAC, 60 Hz ULC
4100-1324
4100-1325
220/230/240 VAC, 50/60 Hz UL
Digital Emergency Voice/Alarm Communications Equipment*
Model Description Details
4100-1363 25 VRMS output
Flex-35, 35 W Amplifier, constant
supervision compatible
Includes three on-board
Class B audio NACs;
power is supplied from
an EPS+, EPS, or XPS
NAC rating = 1.4 A
35 W, or 100
speakers
4100-1364 70.07 VRMS output NAC rating = 0.5 A
4100-1326 25 VRMS output
Flex-50, 50 W Amplifier, constant
supervision compatible
NAC rating = 2 A
50 W, or 100
speakers
4100-1327 70.7 VRMS output NAC rating = 0.707 A
100 W Digital Amplifiers with Power Supply, Constant Supervision Compatible
Model/Output Voltage
Power Supply Input/Listing Description Details
25 VRMS 70.7 VRMS
4100-1328 4100-1329 120 VAC, 60 Hz UL
Primary
100 W
Amplifier
Includes six, Class B audio NACs;
NAC rating = 50 W or 100 speakers
maximum; 2 A @ 25 VRMS;
1.4 A @ 70.7 VRMS
ULC
models
have low
battery
dropout
circuit
4100-1330 4100-1331 120 VAC, 60 Hz ULC
4100-1332 4100-1333 220/230/240 VAC, 50/60 Hz UL
4100-1334 4100-1335 120 VAC, 60 Hz UL
Backup
100 W
Amplifier
Uses the six Class B NACs of primary
amplifier
4100-1336 4100-1337 120 VAC, 60 Hz ULC
4100-1338 4100-1339 220/230/240 VAC, 50/60 Hz UL
Options for use with either Analog or Digital Amplifiers
Model Description Details and Mounting Reference
4100-1245
Flex-35/50 Expansion NAC Module; adds three
Class B audio NACs
Choose
one per
amplifier
Mounts on Flex-35/50 assembly; NAC ratings = 1.5 A, 35/50 W,
or 100 speakers maximum; Supv = 8 mA, Alarm = 60 mA
4100-1246
Flex-35/50 Class A Adapter Module; converts
three on-board NACS to Class A operation
Mounts on Flex-35/50 assembly; NAC ratings = 2 A, 50 W, or
100 speakers maximum; Supv =10 mA, Alarm = 30 mA
4100-1248
100 W Amplifier Expansion NAC Module; NAC
ratings = 1.5 A, 50 W, or 100 speakers max.
Choose
one per
amplifier
Provides six additional Class B audio NACs, mounts on 100 W
amplifier assembly; Supv = 17 mA, Alarm = 60 mA
4100-1249
100 W Class A Adapter Module; NAC ratings =
2 A, 50 W, or 100 speakers max.
Converts six on-board NACs to Class A operation, mounts on
100 W amplifier assembly; Supv = 1 mA, Alarm = 60 mA
4100-1259
25 VRMS Output; NAC
rating = 2 A, 50 W, or
100 speakers max.
Constant Supervision Adapter
for three NACs; select per
amplifier output; not
compatible with amplifier NAC
expansion modules;
deactivated when on batteries
Supv = 10 mA
on batteries;
Alarm = 35 mA
Converts three Class B audio NACS to
Class A or Class B Constant Supervision
NACs; mounts on Flex-35/50 or 100 W
amplifier assembly; use two for the six NACs
on 100 W amplifiers
4100-1260
70.7 VRMS Output; NAC
rating = 0.707 A, 50 W,
or 100 speakers max.
Supv = 38 mA
on batteries;
Alarm = 70 mA
Firefighters Telephone Options*
Model Description Size Supv. In Use
4100-1272
Expansion Telephone Control Module with three Class B telephone NACS; required when
telephone circuits are mounted in transponder;
1 Block 80 mA 130 mA
4100-1273 Telephone Class A Adapter Module; mounts on 4100-1272; no additional current required
* Refer to document S4100-0034 for additional audio information. Continued on next page
MINIPLEX Transponder Product Selection (Continued)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Simplex MINIPLEX 4100ES Series and is the answer not in the manual?

Simplex MINIPLEX 4100ES Series Specifications

General IconGeneral
BrandSimplex
ModelMINIPLEX 4100ES Series
CategoryMarine Radio
LanguageEnglish