E-13
Battery maintenance
Service interval: Every 100 hours
1. Remove the filler cap (D). Fluid must be even with the split
ring full mark (A). If not, add distilled water. Reinstall the
cap (D).
2. First, disconnect the negative battery cable (F)
from the battery terminal (B). Second,
disconnect the positive battery cable (E) from
the battery terminal (C).
3. Remove the battery hold-down rods (H) and hold-down bar
(G). Remove battery from the engine compartment.
4. Clean the compartment with a solution of baking soda and
water. Clean the battery terminals (B and C) and cables (E
and F) with a wire brush and battery terminal cleaner until
shiny.
5. Reinstall the battery in the battery compartment. Secure
with the battery hold-down rods (H) and hold-down bar (G).
6. First, reconnect the positive battery cable (E)
to the positive battery terminal (C). Slide the
terminal cover (E) into place. Second,
reconnect the negative battery cable (F) to the
negative battery terminal (B).
A
F
E
D
C
B
G
H

Related product manuals