OPERATING
INSTRUCTIONS
at
ADJ.
LINE.
11.
Press
the
TUBE
TEST
push
button.
Read
the
quality
indication
on
the
meter.
Read
the
DIODES
GOOD
arc
for
diodes
and
rectifiers,
or
the
colored
areas
and
percent
markings
for
all
other
tubes.
12.
Press
the\red
RELEASE
push
button
at
the
left
hand
side
of
the
panel.
All
the
black
push
buttons
will
re-
store
to
their
up
positions.
13.If
the
tube
has
additional
sections
or
conditions
to
be
tested,
leave
the
tube
in
the
socket
and
repeat
the
a-
bove
operations,
beginning
with
step
5.
The
FILAMENT
switch
position
does
not
change
for
any
additional
tests
on
the
same
tube.
14.
After
the
last
section
of
the
tube
has
been
tested
and
the
red
RELEASE
button
has
been
pressed,
remove
the
tube
from
the
socket.
Return
all
TOGGLE
switches
to
0.
15.
Proceed
with
testing
a
new
tube,
beginning
with
step
3.
Or
if
there
are
no
more
tubes
to
be
tested,
rotate
the
LINE
ADJUSTMENT
control
to
its
OFF
position.
A
slide
switch
at
the
end
of
the
potentiometer
opens
the
primary
circuit
of
the
power
transformer
and
turns
the
Model
1000
off.
SECTION
IV
THEORY
OF
OPERATION