4.2 Electrical installation
J3000X, J300X, J300X-40, J50, J50-40,
AC10, AC20, AC40
The two leads from the motor are connected to the terminal
block marked "MOTOR" in the Junction unit/Autopilot
computer. There is no dedicated Port and Stbd output. The
autopilot will automatically set the correct direction during
"Rudder Test".
Refer to Autopilot manual for further details.
J1000B, J101A and J45A
The two leads from the motor are connected to the terminal
block in the Junction unit marked Motor A and B. Interchanging
of the two leads will change the rotary direction of the motor
(see paragraph 5.2).
The Reversible Pump units are operated from 12V DC via the
Junction unit. This 12V output can be reduced by internal trim
potentiometer (RV1) to reduce rudder speed (see paragraph 2.2).