SINAMICS G120
Standard inverters 0.37 kW to 250 kW (0.5 hp to 400 hp)
PM260 Power Modules –
11 kW to 55 kW (15 hp to 75 hp)
4/71
Siemens D 11.1 · 2009
4
Characteristic curves
Derating data
Ambient temperature
High overload (HO) PM260 frame size FSD
High overload (HO) PM260 frame size FSF
Light overload (LO) PM260 frame size FSD
Light overload (LO) PM260 frame size FSF
Note: The operating temperature ranges of the Control Units
should be taken into account. The temperature ranges are
specified in the technical specifications under Control Units.
Installation altitude
System operating voltage
The power units can be operated with 500 V –10 %. In this case,
the power is reduced linearly as required.
0 20 30 10 40
-10 50 C° 60
75
%
50
25
100
74
G_D011_EN_00111
Ambient temperature
Permissible
output current
0 20 30 10 40
-10 50 C° 60
75
%
50
25
100
74
G_D011_EN_00111
Ambient temperature
Permissible
output current
0 20 30 10 40
-10 50 C° 60
75
%
50
25
100
66
G_D011_EN_00110
Ambient temperature
Permissible
output current
G_D011_EN_00206
Permissible
output current
Ambient temperature
75
25
40 50 603020010-10
%
100
50
51
80
100
%
0 1000 2000 3000 4000 m
70
90
60
G_D011_EN_00104
Installation altitude above sea level
Permissible
output current
80
100
%
0 1000 2000 3000 4000 m
77
70
90
60
G_D011_EN_00105
Installation altitude above sea level
Permissible
input voltage
80
100
%
400 500 600 700 800V
70
90
60
760690
450
690
^
=
450
65
Rated
power
Line operating voltage
G_D011_EN_00117