DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
158
4. Remove the
gas-liquid separator
Remove the
gas-liquid separator
from the compressor
support.
5. Remove the nuts
fixing the compressor
Use spanner to
remove the nuts fixing
between compressor
and compressor
support.
6. Remove the suction
and discharge pipes of
compressor
Use gas welding to
heat the suction and
discharge pipes. Then,
pull them out from the
compressor.
Weld by charging
nitrogen for protection,
with the nitrogen
pressure kept at
0.5±0.1kgf/c 󱚸(relative
pressure).
During heating, take
care to prevent the
substances around
from burn due to high
temperature.
7. Remove the
compressor
Remove the
compressor from
compressor support.