DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
172
3. Remove the power cables
of motor and other
components
Remove the cables
connecting the electric
elements in the electric box
to the external elements
(e.g. the power cables of
compressor and motor)
Note: When removing the
connection, make sure to
mark the position of each
cable correctly.
4. Remove the electric box
sub-assembly
Move the electric box
sub-assembly upward from
the middle isolation plate.
5. Mount a new electric box
sub-assembly
Assemble the new
electric box sub-assembly
to correct position
Use the screwdriver to fix
the electric box
sub-assembly to middle
isolation plate and rear side
plate according to
disassembly procedures.
Disconnect the connection wires of
motor and compressor on the
mainboard