DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
171
8. Charge
refrigerant to the
system via liquid
valve
Recharge the
refrigerant to the system
through liquid valve.
The charge volume
must be identical to the
indications on nameplate.
Disassembly and Assembly of electrical parts box
Remark : Before removing the electric box or electric box sub-assembly, make sure that the power has been
cut off.
Step Illustration Handling Instruction
1. Remove the electric box
cover
Cut off the power.
Use the screwdriver to
remove the fixing screws
between electric box cover
and electric box.
Remove the cover from
electric box.
2. Remove the electric box
sub-assembly
Use the screwdriver to
remove the screws fixing
the electric box to middle
isolation plate and rear side
plate.