DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
170
5. Mount the new
electronic
expansion valve
and connect it to
the system pipeline
Use gas welding to
weld the electronic
expansion valve.
Weld by charging
nitrogen for protection,
with the nitrogen
pressure kept at
0.5±0.1kgf/c 󱚸 (relative
pressure).
During heating, take
care to prevent the
substances around from
burn due to high
temperature.
6. Assemble the
coil of electronic
expansion valve
Install the coil of
electronic expansion
valve according to
disassembly procedures.
7. Establish
vacuum inside the
system through
liquid valve
Establish vacuum inside
the system through liquid