DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
192
Removal of Front Panel
Remark: Cut off the power and ensure the front panel and corner cover in good condition during removal.
Step Illustration Handling Instruction
1. Remove the
corner cover
● Pull the corner cover
outward with your hand
to remove it.
2. Remove the
screws
● Use the screwdriver to
rotate the screws to
position, so that you can
loosen the front panel
clamp. (See the arrow for
the screw position)
● There are totally 4
clamps on the four
corners of front panel.
After they are fully
loosened, you can pull
upward to remove the
front panel.
Removal of Water Tray
Remark: Cut off the power. Ensure that the power cable, signal wires and water tray are in good condition.
Step Illustration Handling Instruction
1. Remove the
electric box
cover and
flow-guide loop
● Loosen the screws on
electric box cover and
flow-guide loop.
Remove the front box
cover. Remove the
power cables and signal
wires connected to the
electric elements in the
electric box and
beneath the water tray.