DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
195
Removal of Guide Louver Connecting Rod Sub-assembly
Remark: Cut off the power. Ensure the guide louver in good condition during removal.
Step Illustration Handling
Instruction
1. Remove the
screws
Strip off some of
the thermal
insulation sponge
on the four corners
of front panel.
Then, knock off the
two screws that are
exposed, so that
you can see the
connecting rod
sub-assembly of
the guide louver.
(See the arrow for
the screw position)
2. Remove the
connecting
rod
sub-assembly
Use your hand to
raise the
connecting rod and
pull the connecting
rod away from the
universal joint. Use
the screwdriver to
loosen the
connecting screws.
(The connecting
rod is shown by the
arrow and the
universal joint is as
shown in the circle)