DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
194
Removal of Motor
Remark: Cut off the power and ensure the motor in good condition
Step Illustration Handling Instruction
Removal of Motor
● Use spanner to
loosen the nuts.
Then, pull upward to
remove the motor.
Removal of Stepping Motor
Remark: Cut off the power. Ensure that the stepping motor will not be damaged during removal.
Step Illustration Handling Instruction
Removal of
Stepping Motor
● Use the
screwdriver to
loosen the 2
mounting screws
fixing the stepping
motor. Then,
remove the
stepping motor.