DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
194
Removal of Motor
Remark: Cut off the power and ensure the motor in good condition
Step Illustration Handling Instruction
Removal of Motor
Use spanner to
loosen the nuts.
Then, pull upward to
remove the motor.
Removal of Stepping Motor
Remark: Cut off the power. Ensure that the stepping motor will not be damaged during removal.
Step Illustration Handling Instruction
Removal of
Stepping Motor
Use the
screwdriver to
loosen the 2
mounting screws
fixing the stepping
motor. Then,
remove the
stepping motor.