2. Model Designation
A S C 36 A I - 3 S
3phase
Inverter
Refrigerant type(A - R410A)
Cooling Capacity in HP (x100) HP
Type
SINCLAIR
Air Conditioner
2.1 Regulation of Units Classification
Units classification Code
Outdoor unit GE
Cassette type C
Floor/Ceiling type F
Duct type D
Model Designation
1ASGE-18AI means universal outdoor unit with nominal cooling capacity of 18000Btu, signle phase
power supply of 22
0~240V50Hz, heat pump, DC inverter,T1 condition and refrigerant of R410a .
2ASGE-42AI-3 means universal outdoor unit with nominal cooling capacity of 42000Btu, three phase
power supply of 380
~415V50Hz, heat pump, DC inverter,T1 condition and refrigerant of R410a .
3ASD-24AI means duct type indoor unit with nominal cooling capacity of 24000Btu, single phase
power supply of 22
0~240V50Hz, heat pump, DC inverter,T1 condition and refrigerant of R410a .
Note:1 Ton =12000Btu/h = 3.517kW
NOTES: The universal outdoor units means that the customer
can choose any of three kind of indoor unit to match
the outdoor unit without any change with it.
- small pipe diameter
()ASD-42AI-3 S means duct type indoor unit with nominal cooling capacity of 42000Btu, single phase
power supply of 22
0~240V50Hz, heat pump, DC inverter,T1 condition and refrigerant of R410a,
with small pipe diameter .