3 FUNCTION 
Function  Description 
Memory function 
when unit restarts after power off, it will run on former status, the mode and 
parameter are kept the same 
Remote control function
wireless controller and remote controller can be selected, and the maximum 
control distance of remote controller is 10m. 
Timing function 
it can timing ON/ OFF separately, meanwhile, it can also timing on circularly 
Self-diagnosis with 
alarm function 
Once the unit has malfunction, the malfunction code will be indicated and alarm 
rings immediately 
Sleep function  it can self control for saving energy in energy saving mode. 
Automatic function 
the fan of indoor unit can adjust fan speed automatically based on actual 
demand when cooling or heating under automatic mode 
Cool air proof function 
the fan starts only when the temperature of indoor unit heat exchanger is higher 
than indoor temperature under heating mode 
Weekly Time 
Centralized Control and Weekly Timer Functions: The centralized controller and 
the weekly timer are integrated in the same wire controller. The system has both 
the centralized control and the week timing functions. Up to 16 sets of units can 
be controlled simultaneously by the centralized controller (weekly timer). The 
weekly timer has the function of invalidating the lower unit. The weekly timing 
function is able to realized four timing ON/OFF periods for any unit every day, so 
as to achieve fully automatic operation. No timing control can be set for holidays.
High/low pressure 
protection 
when suction pressure is too low or discharge pressure is too high, compressor 
will stop and unit display malfunction code 
Overload protection 
compressor has its own overheat protection.Once the temperature of 
compressor is higher than allowable level, compressor will stop and only when 
temperature recovery, compressor restart 
Over current protection
once the current of compressor is higher than normal level, compressor will stop 
and unit display malfunction code 
Discharge high 
temperature protection 
once the discharge temperature of compressor is higher than allowable value, 
compressor will stop and unit display malfunction code 
Reverse (open) phase 
protection 
once the phase sequence of power supply is incongruent or the phase is absent, 
unit can’t work. 
Anti-high temperature 
protection 
once the heat exchanger temperature of indoor unit is too high, compressor will 
stop. 
Timing ON/OFF display
display and timing turn ON/OFF timeonly with wired controller have this 
function 
Fan speed display 
display the speed (high,medium,low) of fanonly with wired controller have this 
function 
Function model display
cooling mode,dry mode,heating mode,fan modeonly with wired controller have 
this function 
Testing display  display testing modeonly with wired controller have this function 
Temperature display 
display room temperature and set temperatureonly with wired controller and 
remoter board have this function