4 PRODUCT DATA 
4.1 Product Data at Rated Condition 
4.1.1 Duct Type 
Indoor unit    ASD-18AI 
Model 
Outdoor unit  ASGE-18AI
kW 5.0 
Cooling 
Btu/h  
17000 
kW   5.8 
Nominal 
Capacity 
Heating 
Btu/h  19800 
Cooling kW   1.57  
  wer 
Input 
Heating kW   1.53 
EER/COP W/W   3.18/3.79
Indoor Unit    ASD-18AI 
Power Supply   220-240V~/1 Ph/50HZ 
Heat Exchange    Cross Fin Coil 
Type   Centrifugal fan 
Drive   Direct Driver 
Motor Output  kW  0.06 
Air Flow  m3/h  840 
Fan 
Ext. Static Pressure  Pa  60 
Sound Pressure Level(H/M/L)  dB(A)   42/40/38 
Air Filter   Standard washable synthetic 
Drain Piping  mm  φ32×1.5 
Dimensions (W×H×D) 
(Outline/Package) 
mm 
1012×266×736 
/1120×323×795 
Weight(Net/Gross) kg   34/41 
Outdoor Unit   ASGE-18AI
Power Supply   220-240V~/1 Ph/50HZ 
Heat Exchange    Cross Fin Coil 
Type   Axial fan 
Motor Output  kW  0.03 
Fan 
Fan Motor Speed  rpm  850 
Type   ROTARY 
Compressor 
Power Input  W  1630 
Type   R410A 
Control    Electronic Expansion Valve 
Refrigerant 
Charge kg   1.5 
Dimensions (W×H×D) 
(Outline/Package) 
mm 
820×540×320 
/870×590×360 
Weight(Net/Gross) kg  36/40 
Liquid mm   6.35 
Gas mm   12.7 
Max. Length  m  20 
Piping 
Connections 
Max. Height Difference  m  15 
Power