DC INVERTER U-MATCH AIR CONDITIONERS                                    INSTALLATION 
 
  Such a place where is 1m or more away from other electric appliances such as television, audio 
device, etc. 
  Avoid a location where there is heat source, high humidity or inflammable gas. 
  Do not use the unit in the immediate surroundings of a laundry, a bath, a shower or a swimming 
pool. 
  Be sure that the installation conforms to the installation dimension diagram. 
  The space around the unit is adequate for ventilation 
1.2.3 Caution for Installation 
  Adjust the distance from the unit to the ceiling slab beforehand (Refer to Figure 1-2-1). 
  Fix the hanger bracket to the suspension bolt (Refer to Figure 1-2-2). 
  Make sure that extended suspension bolt from the ceiling stays inside the arrowed position. 
Readjust the hanger bracket when it is outside the arrowed position. (Refer to Figure 1-2-3)   
  Suspension bolt stays inside the cap of indoor unit .Never remove the cap. Lift the unit and slide 
forward unit the dent. (Refer to Figure 1-2-4) 
  Screw tightly both hanger bracket setting bolts (M8) (Refer to Figure 1-2-2) 
  Screw tightly both hanger bracket fixing bolts (M6) to prevent the movement of the indoor unit. 
(Refer to Figure 1-2-2) 
  Adjust the height by turning the nut with a spanner. Insert the spanner from the hanger bracket 
opening. (Refer to Figure 1-2-5) 
   
 
Hanger bracket Figure 1-2-1                             Figure 1-2-2 
 
 
Figure 1-2-3 Hanger bracket                                       Figure 1-2-4 
In case of hanging: 
It is possible to install using inward facing hanger bracket by not removing the brackets from the indoor 
unit. (Refer to Figure 1-2-6) Be sure to use only the specified accessories and parts for installation work.