Operating Procedures / Photos
Screw off the screws fixing the electric box cover
and then open the cover, next unscrew the screws
fixing
the toggle switch on the cover, at last re-
move
the cover out.
4. Disassemble the electric box cover
5.
Disassemble water tray
Electric box cover
5. Disassemble the electric box
Screw off the grounding wire of the evaporator,
remove the
temperature sensor for the pipe, put
out
the connection lines for the indoor motor.
Screw
off the screws fixing the electric box. Re-
move
the electric box.
Grounding wire
Connect
or
Claslp
Water tray
Connector
Tube Sensor
Screws
Loosen the clasp of the front and rear of
water tray sub-assy and lift them up, pull
out of the connection wire of swing motor,
then can take out the water tray sub-assy.
Note: Due to water tray is connected with
the water drainage pipe, please pay more
more attention do not hurt the fin on evaporator.