8.2 This function manual is applicable to export mobile AC: AMC-12AN.
There are two units for temperature display of mobile AC:Centigrade and Fahrenheit.
The unit for temperature is centigrade in this function manual.
If there is Fahrenheit, the transition relation is TFahrenheit=TCentigradex1.8+32.
8.2.1 Basic Functions of System
After the unit is energized, the interval of start-up time for compressor is no less than 3min under any
conditions; when the compressor is started, the unit is off without the temperature change in 6min.
Ƶ Working conditions and process of cooling
a) When Tabm.Tpreset + 1ć (2), the unit will start to run in cooling mode, the compressor and kick
motor start to run, and fan motor runs under preset fan speed.
b) When Tabm. Tpreset - 1ć (2), the compressor and kick motor stop to run, and fan motor runs
under preset fan speed.
c) When Tpreset - 1ć (2)<Tamb.<Tpreset + 1ć (2), the unit will keep the current running status.
Under this mode, the temperature setting range is 61-86 (16ć-30ć).
Anti-freeze protection period
min
compressor
upper fan motor
l
ower fan motor
run
stop
setting fan speed
8. Function and control

Other manuals for Sinclair MOBILE Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sinclair MOBILE Series and is the answer not in the manual?

Sinclair MOBILE Series Specifications

General IconGeneral
BrandSinclair
ModelMOBILE Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals