EasyManua.ls Logo

Sit 650 DELTA - SHUTDOWN PERFORMANCE TEST

Sit 650 DELTA
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
650 DELTA USE AND INSTALLATION INSTRUCTIONS
WARNING!
Fire or Explosion Hazard.
Can cause severe injury or death.
Perform the safety shutdown check any time work is done on a gas system.
1. Place the appliance in operation. The pilot and main burners should be lit.
2. Place gas control knob in PILOT position. Main burner should extinguish and pilot should
remain lit.
3. Extinguish pilot flame. Pilot gas safety shutoff proves complete shutdown due to the fact the
safety shutoff valve prohibits main burner and pilot gas flow.
4. Wait at least five minutes for the safety magnet to reset and residual gas to clear from the
combustion chamber.
5. Relight pilot burner and operate the system through one complete cycle to ensure all functions
operate correctly.
SHUTDOWN PERFORMANCE TEST