17
SKOPE Centaur Series
Servicing
User Manual
Troubleshooting
Complaint Possible Cause Repair
1. Cabinet not
operating and
no controller
display:
Loss of power supply. Check that the cabinet
power switch is turned on
(see page 10).
Check mains power supply.
2. Power
consumption
is higher than
expected:
Unit operating too hot. Clean condenser. Ensure
the cabinet is installed with
good ventilation around the
refrigeration unit.
Cabinet doors are opened
excessively.
Keep door/s open for
minimum time.
3. Product is too
warm and
spoiling:
Restricted cabinet airflow. Ensure product is not
blocking airflow slots and the
product is no closer than
75mm from the cabinet top.
Temperature setpoint is too
warm.
Adjust setpoint (see
page 13).
Food preparation covers
raised for extended periods.
The covers must stay closed
when not in use (see
page 9).
4. Warm cabinet
temperatures
and/or
compressor
operating for
long periods
(more than 1
hour):
Blocked condenser. Clean condenser coil (see
page 15).
Poor refrigeration unit
ventilation.
Ensure the cabinet is
installed with good
ventilation around the
refrigeration unit.