41
Problem Probable cause Remedy
No power Battery is too warm
— red LED blinks on Battery
Let the Battery cool down
Battery is too cold
— below -10°C (14°F)
Let the Battery warm up
Battery not charged Check the battery, change when empty
Power Supply not switched on Activate power supply
Too short a press on Power Button Press for 2 secounds
Emergency Stop engaged Disengage Emergency Stop
Power LED turns red Emergency Stop engaged Disengage Emergency Stop
Problem with Battery or Power Supply
Try another Battery or Power Supply
Error detected in Ascender Restart: LED Green — OK
LED Red — Contact SKYLOTEC distributor or SKYLOTEC
Remote control does not
connect
Ascender is not switched on Switch Ascender on
Distance too far
Get closer to Ascender
Signal interference Get closer to Ascender
Remote Control from another
Ascender
Find correct Remote Control