DSAT-300 USER GUIDE 25
Document Rev. 1.015 DOC0594 Page 25 of 28
Restricted Proprietary and Confidential Information
15 TECHNICAL DETAILS
TECHNICAL DETAILS
Voltage Requirements
11 to 30 VDC nominal (airplane power)
Absolute Maximum Voltage
40 VDC
Power Requirements
1 A at 14 VDC, 0.5A at 28 VDC when charging
TEMPERATURE RANGE OPERATIONAL
Batteries Installed
-20 °C to 60 °C
Batteries Removed
-30 °C to 60 °C
Batteries Charging
0 to 45 °C
TEMPERATURE RANGE STORAGE
Batteries Installed
-20 °C to 50 °C
Batteries Removed
-40 °C to 85 °C**
** Storage at high temperatures for an extended period of time will decrease the life time of onboard components
including the internal battery.
NOTE: Operation with extended temperature range:
The limiting factor for the operational temperature range of the unit is the temperature rating of the Li-Ion batteries.
When using the unit at extreme temperatures, STS recommends removing the batteries (see DOC 0595 Battery
Removal Instructions) allowing the unit to run within a wider temperature window. Please also refer to DOC 0595
for proper handling procedures of the circuit board

Other manuals for Skytrac DSAT-300E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Skytrac DSAT-300E and is the answer not in the manual?

Skytrac DSAT-300E Specifications

General IconGeneral
BrandSkytrac
ModelDSAT-300E
CategoryConference System
LanguageEnglish

Related product manuals