Repair Parts and Maintenance Guide
76
Sensor Flushometers
The information contained in this document is subject to change without notice.
Repair Parts and Maintenance Guide
Optima
®
Flushometers
Code No. Description
5325056 O-ring – 6 per package
REGULATOR
FLEX TUBE
DIAPHRAGM
O-RING
0-RING
REGULATOR (MUST
BE INSTALLED
PAST 0-RING)
FLEX TUBE
DIAPHRAGM
The  ush volume of the  ex tube
diaphragm kit is controlled by the
regulator. Regulators are identi ed by
color. Some  ex tube diaphragm kits
are supplied with multiple regulators.
The installer must make sure the
proper regulator is used when
installing the  ex tube diaphragm kit.
OLD STYLE DIAPHRAGM INSIDE PARTS
QUAD RING
OLD STYLE KITS ABOVE
ARE OBSOLETE.
SEE CHART FOR
REPLACEMENT.
The 5325813
Quad Ring is
still available.
Code No. Part No. Description
5325813 EBV-18 Quad Ring –
12 per package
REGULATOR (Sold 6 per package)
Code No. Part No. Description Regulator Color
5325122 EBV-95 Urinal-0.5 gpf/1.9 Lpf GREEN
5325122 EBV-95 Urinal-1.0 gpf/3.8 Lpf GREEN
5325129 EBV-102-2 Urinal-1.5 gpf/5.7 Lpf BLACK
5325130 EBV-102-1 Urinal-3.5 gpf/13.2 Lpf WHITE
5325122 EBV-95 Closet-1.28 gpf/4.8 Lpf GREEN
5325122 EBV-95 Closet-1.6 gpf/6.0 Lpf GREEN
5325130 EBV-102-1 Closet-3.5 gpf/13.2 Lpf WHITE
5325128 EBV-101 Closet-2.4 gpf/9.0 Lpf BLUE
The EBV-1020-A and EBV-1022-A kits are supplied with multiple  ush volume regulators. The installer must use
the correct regulator when installing the kit.
Use To Replace
Code No. Part No. Description Color* Old Part No.
3325098 EBV-1026-A URINAL GREEN — 0.125 gpf/0.5 Lpf
3325003 EBV-1023-A URINAL GREEN EBV-32-A-U-0.5 (0.5 gpf/1.9 Lpf
‡)
3325000 EBV-1022-A URINAL GREEN EBV-32-A-U-1.0 (1.0 gpf/3.8 Lpf
†)
3325000 EBV-1022-A URINAL BLACK EBV-32-A-U-1.5 (1.5 gpf/5.7 Lpf
†)
3325001 EBV-1020-A URINAL WHITE EBV-20-A-U-3.5 (3.5 gpf/13.2 Lpf
†)
3325031 EBV-1024-A CLOSET GREEN — 1.28 gpf/4.8 Lpf
3325001 EBV-1020-A CLOSET GREEN EBV-10-A-C-1.6 (1.6 gpf/6.0 Lpf
†)
3325014 EBV-1021-A CLOSET BLUE EBV-10-A-C-2.4 (2.4 gpf/9.0 Lpf)
3325001 EBV-1020-A CLOSET WHITE EBV-10-A-C-3.5 (3.5 gpf/13.2 Lpf
†)
3325001 EBV-1020-A CLOSET WHITE EBV-10-A-C-4.5 (4.5 gpf/17.0 Lpf
§_
The EBV-1020-A and EBV-1022-A kits are supplied with multiple regulators.
A 0.5 gpf (1.9 Lpf) urinal kit can be converted to a 1.0 gpf (3.8 Lpf) by cutting and removing the smooth A-164  ow ring from the guide.
§ For a 4.5 gpf (17.0 Lpf) water closet  ush, use the EBV-1020-A kit with the white regulator, and cut and remove the A-164  ow ring from
the guide.
* Color of regulator to be used with  ex tube diaphragm to obtain the listed  ush volume.
FLEX TUBE DIAPHRAGM KITS
REGULATORS
Repair Parts and Maintenance Guide
77
Sensor Flushometers
The information contained in this document is subject to change without notice.
Repair Parts and Maintenance Guide
Optima
®
Flushometers
(All Optima products manufactured prior to May, 2003)
1. Remove battery cover and batteries from existing
sensor module.
3. Unscrew (counterclockwise) the existing solenoid valve from
the base plate.
4. Remove white plastic seat and O-rings that are located inside
the housing.
Back View
5. Remove clear plastic housing from the threaded end of new
operator by unscrewing (counterclockwise). It is normal to fi nd
water inside this housing.
8. Reconnect the white plastic connectors on the side of the
module. Slide the white connector into the clip to secure. Tuck
wiring in close to module. If valve runs, tighten solenoid further.
7. Reinstall batteries in the correct position and reattach
battery door.
Front View
6. Make sure O-ring is installed on the gray housing of the new
operator. Install isolated operator by threading it (clockwise)
into the housing. Tighten with fi ngers beyond just snug.
2. Disconnect the white plastic connector that connects
the black and red wires on the side of the module.
SOLENOID REPLACEMENT
Code No. Part No. Description
3325462 EBV-144-A Solenoid operator
For use with black Optima Plus
®
EBV-26-A
modules only (produced 1992-2003).
For G2 Optima Plus
®
modules (identi ed by a
blue module) use the EBV-136-A solenoid.
372626_Master_Book_ccg.indd 74 9/18/17 7:52 AM