TEST AND ADJUSTMENT VALUES FOR THE BATTERY
TEST AND ADJUSTMENT VALUES FOR THE BATTERY
TEST AND ADJUSTMENT VALUES FOR THE BATTERY
On model 414 the battery has to be disconnected for the tests to avoid any damage.
Perform test for remaining vehicles with battery installed and connected where possible. Do not connect
tester to jump start or charging terminal point, always connect it directly with the battery.
Battery tester
gotis://E_15/54_02. 0
All test steps and entries must be performed thoroughly, otherwise the test result will be distorted.
Test prerequisites:
l Tester with software release 2.0
l Ignition off
l Rotary light switch in position "0"
If the message "Surface voltage" is displayed during the test, the tester has detected that the battery
voltage is apparently too high. This increased voltage can be reduced as follows:
l Battery installed: Decrease increased voltage as per the specifications of the tester (e.g. switch on
driving lights).
l Battery removed: reduce increased voltage using a suitable volt/amp(s) tester (load battery for approx.
60 s with 20 A to 30 A amps).
As an example, the test procedure for passenger cars is described below.
l Audio component (e.g. radio) switched off
l Battery voltage higher than 12.4 V
l Good contact of the tester on the battery
1. Clip tester (1) on to battery.
Number Designation 60 Ah VRLA 60 AH 62 AH
BE54.10-P-1002-
01A
Cold test current as per EN A 680 510 480
Number Designation 70 Ah VRLA 74 AH 80 Ah VRLA 84 AH
BE54.10-P-1002-
01A
Cold test current as per
EN
A 760 680 800 700
Number Designation 90 Ah VRLA 95 Ah VRLA 100 Ah
BE54.10-P-1002-
01A
Cold test current as per EN A 950 850 760
2010 Smart Fortwo Passion
2009 ACCESSORIES & BODY, CAB Electrical System, Equipment & Instructions - Fortwo (Cabrio)
15 октября 2019 г. 19:12:10 Page 15 © 2011 Mitchell Repair Information Company, LLC.