Pumping time:adjustthevacuumtime,generally20~30seconds,dependingon
thevacuumtableafterwork,generalvacuumgauge.Itcanreach0.06~0.08MPa.
Sealing time:adjusttheheatingtime,usuallyabout1.5seconds,dependingon
thematerialofthevacuumbag.
Cooling time:about3seconds.
Work instruction:Whenworking,theworkindicatorison;whennotworking,the
workindicatoriso.
Setting button:
•Whenthepoweristurnedon,“FF”isdisplayedonthepaneltoindicatethe
standbystate.
•Pressthesetbuttontolightupthepumpingtimeindicatorandenterthe
pumpingtimesetting.Usetheincreasebuttonordecreasebuttontosetthe
requiredtimevalue.
•Pressthesetbuttonagaintolightthetimeindicator,enterthesealingtime
setting,andusetheincreasebuttonordecreasebuttontosettherequiredtime
value;
•Pressthesettingbuttonagaintosetthecoolingtimeindicatortolight,enter
thecoolingtimesetting,andusetheincreasebuttonordecreasebuttontoset
therequiredtimevalue;
•PresstheSETbuttonagaintoreturntothestandbystate.“FF”isdisplayed
onthepanel.
Add button:Increasethetimevalue.
Decrease button: Reducesthetimevalue.
Stop button: Usedwhenthereisaproblemwiththemachineoroperationor
whenitisstoppedurgently.