EasyManua.ls Logo

SMC Networks VQC1000 Series - VQC1000 Manifold Specification Sheet; How to Order Manifolds; Stations and Cylinder Port Size

Default Icon
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
q How to order manifolds
VV5QC 1 1 08 SDQ B
Base-Mounted plug-in
Series VQC1000
Stations
01
⋅⋅⋅
1 station
⋅⋅⋅
Electrical entry/Cable length
Nil
None
All stations with back pressure check valve
Note 1)
With DIN rail (rail length: standard)
With DIN rail (rail length: special)
Note 2)
Special wiring specifications
Note 3)
(except for double wiring)
With name plate
External pilot
Note 4)
Direct exhaust with built-in silencer
Note 5)
B
D
D
K
N
R
S
D-side
entry
Kit, Cable length
FD0
FD1
FD2
FD3
PD0
PD1
PD2
PD3
PDC
TD0
SD0
SDQ
SDN
SDA1
SDA2
D-sub connector kit (25P) without cable
D-sub connector kit (25P) with 1.5m cable
D-sub connector kit (25P) with 3.0m cable
D-sub connector kit (25P) with 5.0m cable
Flat ribbon cable kit (26P) without cable
Flat ribbon cable kit (26P) with 1.5m cable
Flat ribbon cable kit (26P) with 3.0m cable
Flat ribbon cable kit (26P) with 5.0m cable
Flat ribbon cable kit (20P) without cable
Note 1)
Terminal block box kit
1 to 10 (20)
Stations
Note 2)
1 to 12 (24)
1 to 12 (24)
1 to 12 (24)
1 to 8 (16)
1 to 9 (18)
C6
2
3
1
Cylinder port size
C3
C4
C6
M5
CM
L3
L4
L6
L5
B3
B4
B6
B5
LM
With ø3.2 One-touch fitting
With ø4 One-touch fitting
With ø6 One-touch fitting
M5 thread
Mixed sizes and with port plug
Top ported elbow
Wtih ø3.2 One-touch fitting
Top ported elbow
With ø4 One-touch fitting
Top ported elbow
With ø6 One-touch fitting
Bottom ported elbow
With ø3.2 One-touch fitting
Bottom ported elbow
With ø4 One-touch fitting
Bottom ported elbow
With ø6 One-touch fitting
M5 thread
Elbow port, mixed sizes
M5 thread
Note 1) Indicate the size in the
specification sheet in
the case of CM and LM.
Note 2) Symbols for inch sizes are
as follows:
<For One-touch fittings>
N1: ø1/8"
N3: ø5/32"
N7: ø1/4"
NM: Mixed
t
Input block (Fill out for I/O unit only)
Nil
Without SI unit/input block (SD0)
Without input block
With 1 input block
With 8 input blocks
0
1
8
r SI unit COM
Nil
DeviceNet
EX500EX250
DeviceNet
PROFIBUS-DP
PROFIBUS-DP
Remote
I/O
SI unit COM
+COM
COM
N
Input/Output serial kit (EX250)
Serial kit without SI unit
Serial kit DeviceNet compatible
Serial kit PROFIBUS-DP compatible
Decentralized wiring serial kit (EX500)
Serial kit for Remote I/O
Serial kit DeviceNet/PROFIBUS-DP compatible
w How to order applicable valves
VQC 1 0
5
E B
0
Y
1
Series VQC1000
FEDCB
B
A
A
1
2
3
4
5
A
Note)
B
Note)
C
Note)
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
Dual 3-port valve (N.C. + N.C.)
Dual 3-port valve (N.O. + N.O.)
Dual 3-port valve (N.C. + N.O.)
Manual override
Nil
Non-locking push type (tool required)
Slotted locking type (tool required)
Locking type (manual)
B
C
D
Coil voltage
5
24VDC
Seal type
Type of actuation
0
1
Metal seal
Rubber seal
F
E
Light/Surge voltage
suppressor
With
Without
Note)
E
Note) Not applicable to S Kit.
Nil
23
Manifold Specification Sheet
Series VQC1000: Base-Mounted Type/Plug-in Unit
VV5QC 1 1 08 FD1 B
1
4 5 6 7
C6
2 3 8
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅Fill out for I/O serial kit only.
The maximum number of stations
differs depending on the electrical
entry. Refer to e.
Note 1) P Kit: Order the cable assembly separately for the type 20P.
Note 2) Numbers inside ( ) indicate the maximum number of solenoids for mixed single and
double wiring. The maximum number of stations is determined by the total number of
solenoids. In the case of mixed wiring, use the option symbol "-K".
Note) Leave the box blank for the SI unit COM without input block (SD0).
u Input block COM (Fill out for I/O unit only)
Nil
PNP (+)
or without SI unit/input block (SD0)
NPN ()
N
Note 1) When using the back pressure check valve
for the necessary stations only, enter the
back pressure check valve part no. and
indicate the number of manifold stations in
the specification sheet.
Note 2) For special DIN rail length, indicate "D."
(Enter the number of stations inside ).
Example: -D08
In this case, stations will be mounted on a
DIN rail for 8 stations regardless of the
actual number of manifold stations.
Indicate "-D0" for the option without DIN rail.
Note 3) Be sure to indicate the wiring specifications
in the specification sheet.
Note 4) For external pilot option, "-R", indicate the
external pilot specification "R" for the
applicable valves as well.
Note 5) The built-in silencer type does not satisfy the
IP67 standard.
⋅⋅⋅⋅⋅⋅⋅
⋅⋅⋅⋅⋅⋅⋅
y Input block type
(Fill out for I/O unit only)
Nil
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs (3 pins)
1
2
3
D-side
Stations⋅⋅⋅⋅1⋅⋅⋅⋅2⋅⋅⋅⋅⋅3⋅⋅⋅⋅4⋅⋅⋅⋅5⋅⋅⋅⋅6⋅⋅⋅⋅7⋅⋅⋅⋅8⋅⋅⋅⋅⋅⋅n
U-side
F P T
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Kit
//
S
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Kit
Note) Available for the rubber seal type only.
C
Function
Nil
K
Note 1)
N
R
Y
Standard type (1W)
High voltage type (1.0MPa)
Negative COM
External pilot
Low wattage type (0.5W)
F Kit
P Kit
T Kit
S Kit
i Options
The top ported elbow is LNand
the bottom ported elbow is BN.
When specifying two or more options, list symbols
in alphabetical order. Example: -BRS
Note 1) Available for the metal seal type only.
Wnen specifying two or more options, list
symbols in alphabetical order.
Stations are numbered in ascending order
from the D-side.

Other manuals for SMC Networks VQC1000 Series