q How to order manifolds
q Stations
01
⋅⋅⋅
1 station
⋅⋅⋅
i Options
Nil
None
All stations with back pressure check valve
Note 1)
With DIN rail (rail length: standard)
With DIN rail (rail length: special)
Note 2)
Special wiring specifications
Note 3)
(except for double wiring)
With name plate
External pilot
Note 4)
Direct exhaust with built-in silencer
Note 5)
B
D
D
K
N
R
S
w Cylinder port size
C4
C6
C8
CM
L4
L6
L8
B4
B6
B8
LM
With ø4 One-touch fitting
With ø6 One-touch fitting
With ø8 One-touch fitting
Mixed or with port plug
Top ported elbow
With ø4 One-touch fitting
Top ported elbow
With ø6 One-touch fitting
Top ported elbow
With ø8 One-touch fitting
Bottom ported elbow
With ø4 One-touch fitting
Bottom ported elbow
With ø6 One-touch fitting
Bottom ported elbow
With ø8 One-touch fitting
Elbow port, mixed sizes
t
Input block (Fill out for I/O unit only)
Nil
Without SI unit/input block (SD0)
Without input block
With 1 input block
With 8 input blocks
0
1
8
w How to order applicable valves
VQC 2 0
5
E B
0
Y
1
Series VQC2000
FEDCBA
D
Coil voltage
5
24VDC
B
Seal type
0
1
Metal seal
Rubber seal
Manual override
Nil Non-locking push type (tool required)
Slotted locking type (tool required)
Locking type (manual)
B
C
F
E
Light/Surge voltage
suppressor
With
Without
Note)
Note) Not applicable to S Kit.
Nil
E
25
Manifold Specification Sheet
Series VQC2000: Base-Mounted Type/Plug-in Unit
The maximum number of stations
differs depending on the electrical
entry. Refer to e.
Note 1) When using the back pressure check valve
for the necessary stations only, enter the
back pressure check valve part no. and
indicate the number of manifold stations in
the specification sheet.
Note 2) For special DIN rail length, indicate "D."
(Enter the number of stations inside .)
Example: -D08
In this case, stations will be mounted on a
DIN rail for 8 stations regardless of the actual
number of manifold stations.
Indicate "-D0" for the option without DIN rail.
Note 3) Be sure to indicate the wiring specifications
in the specification sheet.
Note 4) For external pilot option, "-R", indicate the
external pilot specification "R" for the
applicable valves as well.
Note 5) The built-in silencer type does not satisfy the
IP67 standard.
⋅⋅⋅⋅⋅⋅⋅
⋅⋅⋅⋅⋅⋅⋅
y
Input block type
(Fill out for I/O unit only)
Nil
Without input block
M12, 2 inputs
M12, 4 inputs
M8, 4 inputs (3 pins)
1
2
3
D-side Stations⋅⋅⋅⋅1⋅⋅⋅⋅2⋅⋅⋅⋅3⋅⋅⋅⋅⋅4⋅⋅⋅⋅5⋅⋅⋅⋅⋅6⋅⋅⋅⋅7⋅⋅⋅⋅8⋅⋅⋅⋅n U-side
VV5QC 2 1 08 SDQ B
Base-Mounted plug-in
Series VQC2000
C8
VV5QC 2 1 08 FD1 B
1
4 5 6 7
C8
2 3 8
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅Fill out for I/O serial kit only.
F P T
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Kit
//
S
⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅⋅
Kit
A
1
2
3
4
5
A
Note)
B
Note)
C
Note)
2-position single
2-position double
3-position closed center
3-position exhaust center
3-position pressure center
Dual 3-port valve (N.C. + N.C.)
Dual 3-port valve (N.O. + N.O.)
Dual 3-port valve (N.C. + N.O.)
Type of actuation
Note) Available for the rubber seal type only.
C
Note 1) Available for the metal seal type only.
When specifying two or more options,
list symbols in alphabetical order.
Function
Nil
K Note 1)
N
R
Y
Standard type (1W)
High voltage type (1.0MPa)
Negative COM
External pilot
Low wattage type (0.5W)
e Electrical entry/Cable length
D-side
entry
Kit, Cable length
FD0
FD1
FD2
FD3
PD0
PD1
PD2
PD3
PDC
TD0
SD0
SDQ
SDN
SDA1
SDA2
D-sub connector kit (25P) without cable
D-sub connector kit (25P) with 1.5m cable
D-sub connector kit (25P) with 3.0m cable
D-sub connector kit (25P) with 5.0m cable
Flat ribbon cable kit (26P) without cable
Flat ribbon cable kit (26P) with 1.5m cable
Flat ribbon cable kit (26P) with 3.0m cable
Flat ribbon cable kit (26P) with 5.0m cable
Flat ribbon cable kit (20P) without cable
Note 1)
Terminal block box kit
1 to 10 (20)
Stations
Note 2)
1 to 12 (24)
1 to 12 (24)
1 to 12 (24)
1 to 8 (16)
1 to 9 (18)
Input/Output serial kit (EX250)
Serial kit without SI unit
Serial kit DeviceNet compatible
Serial kit PROFIBUS-DP compatible
Decentralized wiring serial kit (EX500)
Serial kit for Remote I/O
Serial kit DeviceNet/PROFIBUS-DP compatible
Note 1) P Kit: Order the cable assembly separately for type 20P.
Note 2) Numbers inside ( ) indicate the maximum number of solenoids for mixed single and
double wiring. The maximum number of stations is determined by the total number of
solenoids. In the case of mixed wiring, use the option symbol "-K".
F Kit
P Kit
T Kit
S Kit
r SI unit COM
Nil
N
DeviceNet
EX500EX250
DeviceNet
PROFIBUS-DP
PROFIBUS-DP
Remote I/O
SI unit COM
+COM
COM
Note) Leave the box blank for the SI unit COM without input block (SD0).
u Input block COM (Fill out for I/O unit only)
Nil
PNP (+)
or without SI unit/input block (SD0)
NPN ()
N
Note 1) Indicate the size in the
specification sheet in the
case of CM and LM.
Note 2) Symbols for inch sizes are
as follows:
<For One-touch fittings>
N3: ø5/32"
N7: ø1/4"
N9: ø5/16"
NM: Mixed
When specifying two or more options, list symbols
in alphabetical order. Example: -BRS
The top ported elbow is LNand
the bottom ported elbow is BN.
Stations are numbered in ascending order
from the D-side.

Other manuals for SMC Networks VQC1000 Series