2
How to Order Valves
Manifold Options
1
2
VQC1000
VQC2000
Series
Type of actuation
VQC 1 1 0
5
Coil voltage
Manual override
Seal type
Function
Light/Surge voltage suppressor
Note 1) For metal seal type only.
Note 2) When specifying more than
one option, enter symbols in
alphabetical order.
2-position single
2-position double (metal)
2-position double (rubber)
3-position closed center
3-position exhaust center
3-position pressure center
1
4-position dual 3-port valve
(A)
4-position dual 3-port valve
(B)
4-position dual 3-port valve
(C)
A
B
C
2
3
4
5
Metal seal
Rubber seal
Note) Not applicable to S Kit.
0
1
With
Without
Note)
Nil
E
Standard type (1W)
High voltage type (1.0MPa)
Negative COM
External pilot
Low-wattage type (0.5W)
Nil
K
N
R
Y
24VDC
12VDC
5
6
Nil:
Non-locking
push type
(Slotted)
B: Locking type
(Slotted)
C: Locking type
(Manual)
SUP block plate
VVQ1000-16A
VVQ2000-16A
Blanking plug
KQ2P-
VVQC1000-19A- -
D
S
C3
C4
C6
M5
EXH block plate assembly
Back pressure check valve
Assembly [-B]
VVQ1000-18A, VVQ2000-18A
Name plate [-N]
VVQ1000-N-Stations (1 to max. no. of stations)
VVQ2000-N-Stations (1 to max. no. of stations)
Direct EXH outlet with
built-in silencer [-S]
AB
PEBEA
AB
EAPEB
AB
P
EA
EB
AB
EBPEA
1
5
3
4
2
N.C. N.C.
1
5
3
4
2
N.O. N.O.
1
5
3
42
N.C. N.O.
AB
PEA EB
AB
PEA EB
Blanking plate assembly
VVQ1000-10A-1
VVQ2000-10A-1
Perfect block
VVQ1000-FPG-
VVQ2000-FPG-
Dual flow fitting assembly
VVQ1000-52A-C8
VVQ2000-52A-C10
Blanking plate with connector
VVQ1000-1C-
(VQC1000 only)
Electrical wiring
specifications [-K]
Individual SUP spacer
VVQ1000-P-1-C6
VVQ2000-P-1-C8
Elbow fitting assembly
VVQ1000-F-L
VVQ2000-F-L
Port plug
VVQ0000-58A
(For VQC1000)
VVQ1000-58A (For VQC2000)
Individual EXH spacer
VVQ1000-R-1-C6
VVQ2000-R-1-C8
EXH block plate
VVQ2000-19A
DIN rail mounting bracket [-D]
VVQ1000-57A
VVQ2000-57A
Silencer (EXH port)
AN200-KM8 (For VQC1000)
AN200-KM10 (For VQC2000)
D-sub connector
Connector terminal no.
Terminal no.
Station 1
Station 2
Station 3
Station 4
Station 5
Station 6
Station 7
Station 8
SOL. A
SOL. A
SOL. A
SOL. A
SOL. A
SOL. B
SOL. A
SOL. B
SOL. A
SOL. B
SOL. A
SOL. B
COM
1
14
2
15
3
16
4
17
5
18
6
19
13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Standard manifolds are for double
wiring, but mixed wiring (single
and double wiring) can be speci-
fied as options.
0
Note)
Note)
Note)
Note 1)
Note) For rubber seal type only.
CYL
to
port
C6 (SUP port)
ø6 One-touch fitting
C6 (EXH port)
ø6 One-touch fitting
1
2
3
4
5
9
8
7
6
Exhaust port
(-S)
(-T)
(-S)
(-T)
Conforms to IP40
Conforms to IP40
VQC1000/2000
Base-Mounted Type
Plug-in Unit
Conforms to IP40