Installation
71
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 - 30/37 mbar AUX SR RR FB UR
Rated heating capacity (kW)
1.10 1.70 2.60 2.90 4.10
Nozzle diameter (1/100 mm)
48 62 76 82 95
Reduced flow rate (W)
400 500 700 950 1500
Primary air (mm)
3.5 8 2 5 open
Rated flow rate G30 (g/h)
80 124 189 211 298
Rated flow rate G31 (g/h)
79 121 186 207 293
8 LPG G30/31 - 37 mbar AUX SR RR FB UR
Rated heating capacity (kW)
1.10 1.80 2.60 3.0 4.10
Nozzle diameter (1/100 mm)
48 60 73 80 92
Reduced flow rate (W)
450 500 750 950 1600
Primary air (mm)
3.56246
Rated flow rate G30 (g/h)
80 131 189 218 298
Rated flow rate G31 (g/h)
79 129 186 214 293
9 LPG G30/31 - 50 mbar AUX SR RR FB UR
Rated heating capacity (kW)
1.10 1.70 2.60 3.0 4.10
Nozzle diameter (1/100 mm)
42 54 67 73 85
Reduced flow rate (W)
400 500 750 950 1500
Primary air (mm)
34132.5
Rated flow rate G30 (g/h)
80 124 189 218 298
Rated flow rate G31 (g/h)
79 121 186 214 293
10 Town gas G110 – 8 mbar AUX SR RR FB UR
Rated heating capacity (kW)
1.10 1.80 2.60 2.90 4.10
Nozzle diameter (1/100 mm)
135 175 210 230 310
Reduced flow rate (W)
400 500 750 950 1500
Primary air (mm)
2.5 1.5 0.5 0.5 2.5
11 Town gas G120 – 8 mbar AUX SR RR FB UR
Rated heating capacity (kW)
1.10 1.80 2.60 2.90 4.10
Nozzle diameter (1/100 mm)
128 160 200 220 280
Reduced flow rate (W)
400 500 750 950 1500
Primary air (mm)
2.5 1.5 0.5 0.5 2.5