Installation
70
The nozzles not provided are available at Authorised Service Centres.
8 LPG G30/31 AUX SR R UR2 int. UR2
Rated heating capacity (kW)
1.0 1.8 3.0 0.9 4.0
Nozzle diameter (1/100 mm)
50 65 85 46 98
Pre-chamber (printed on nozzle)
-----
Reduced capacity (W)
400 500 800 400 1600
Rated capacity G30 (g/h)
73 131 218 65 291
Rated capacity G31 (g/h)
71 129 214 64 286
9 LPG G30/31 AUX SR R UR2 int. UR2
Rated heating capacity (kW)
1.1 1.9 2.9 0.9 4.1
Nozzle diameter (1/100 mm)
50 65 81 46 94
Pre-chamber (printed on nozzle)
-----
Reduced capacity (W)
450 550 800 450 1600
Rated capacity G30 (g/h)
80 138 211 65 305
Rated capacity G31 (g/h)
79 136 207 64 300
10 LPG G30/31 AUX SR R UR2 int. UR2
Rated heating capacity (kW)
1.0 1.8 2.9 1.0 4.0
Nozzle diameter (1/100 mm)
43 58 70 43 75
Pre-chamber (printed on nozzle)
(H2) (M) (Y) (H2) (S1)
Reduced capacity (W)
400 500 850 400 1700
Rated capacity G30 (g/h)
73 131 211 73 291
Rated capacity G31 (g/h)
71 129 207 71 286
11 City Gas G110 AUX SR R UR2 int. UR2
Rated heating capacity (kW)
1.0 1.8 2.8 1.0 3.6
Nozzle diameter (1/100 mm)
145 185 260 140 320
Pre-chamber (printed on nozzle)
(/8) (/2) (/3) (/8) -
Reduced capacity (W)
400 500 800 400 1400
12 City Gas G120 AUX SR R UR2 int. UR2
Rated heating capacity (kW)
1.0 1.8 2.8 1.1 3.7
Nozzle diameter (1/100 mm)
135 175 240 130 300
Pre-chamber (printed on nozzle)
(/8) (/1) (/3) (/8) -
Reduced capacity (W)
400 500 800 400 1400