Burner and nozzle characteristics tables
1 Natural Gas G20 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
72 97 115 75+135
Pre-chamber (printed on nozzle)
(X) (Z) (Y) (H1)+(H3)
Reduced capacity (W)
400 500 800 1900
2 Natural Gas G20 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.1 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
72 94 115 75+125
Pre-chamber (printed on nozzle)
(X) (Y) (8) (H1)+(H3)
Reduced capacity (W)
400 500 800 1900
3 Natural Gas G25 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.0 1.8 3.0 4.2
Nozzle diameter (1/100 mm)
72 94 121 75+145
Pre-chamber (printed on nozzle)
(F1) (Y) (F2) (H1)+(H3)
Reduced capacity (W)
400 500 800 1900
4 Natural Gas G25.1 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.1 1.8 3.0 4.1
Nozzle diameter (1/100 mm)
77 100 134 75+138
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (H1)+(F3)
Reduced capacity (W)
400 500 800 1900
6 Natural Gas G27 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.1
Nozzle diameter (1/100 mm)
77 105 138 80+148
Pre-chamber (printed on nozzle)
(F1) (Y) (F3) (H1)+(F3)
Reduced capacity (W)
400 500 800 1900
7 Natural Gas G2.350 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.1
Nozzle diameter (1/100 mm)
94 120 165 100+190
Pre-chamber (printed on nozzle)
(Y) (Y) (F3) (0)+(H3)
Reduced capacity (W)
400 500 800 1900
8 LPG G30/31 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.0 1.8 2.9 4.1
Nozzle diameter (1/100 mm)
50 65 85 46+91
Reduced capacity (W)
400 500 800 1900
Rated capacity G30 (g/h)
73 131 211 305
Rated capacity G31 (g/h)
71 129 207 300
9 LPG G30/31 AUX SR R UR2 (int)+(ext)
Rated heating capacity (kW)
1.1 1.8 2.9 4.2
Nozzle diameter (1/100 mm)
50 62 81 62+62
Pre-chamber (printed on nozzle)
----
Reduced capacity (W)
450 550 800 1900
Rated capacity G30 (g/h)
80 131 211 298
Rated capacity G31 (g/h)
79 129 207 293