EasyManua.ls Logo

Soberlink connect - Device Operating Information and Safety; Safety Precautions

Soberlink connect
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7
Device Operang Informaon
Dimensions 4.75” x 2.5” x 1.25”
Weight 5.3 oz. (150 grams)
Sensor Technology Deep lung, Dart fuel-cell sensor
Battery Type Lithium-ion rechargeable battery, holds 10+ days
Power Supply USB-C charger, Output: 5V 1A
Breath Sample Duration 4 seconds
Operating Temperature 32°F - 122°F (0°C - 50°C)
Sensor Accuracy .+/- .005 BAC
Detection Range .000 - .400% BAC
Calibration Every 1,500 tests
Camera Color, digital, infrared technology
Test Data BAC, time of test, and photo
Components Breathalyzer, mouthpieces, charger, case
Manufactured ISO 9001, 14001, 13485, AS9100, and OHSAS 18001
Warranty 1 year limited
Technical Specications
The user does not need to perform any tests at start up, the Device performs
a self-test when it is powered on and prior to a test submission. The self-test
is meant to verify the proper operation of the test storage memory, alcohol
fuel cell, and imager. Failure of any of these components indicates that the
Device is unable to properly record test data. In this case, an error code is
displayed to the user and testing will not proceed.
Safety
There are no anticipated risks or discomforts utilizing the Device, however, if
the Device is used in rapid succession, dizziness may occur. For correct and
effective use of the Device, it is essential to follow the instructions contained in
this document. The Device should not be used to determine if it is safe for the
user to drive. To ensure proper Device function, keep it fully charged.
The radiated output power of the device is below the FCC/ISED radio
frequency exposure limits when hand-held during operation or when used at
5mm touch distance to the body.