14
Function (19) Door shutting time:
Time setting for sensing door-shutting time as to activate the alarm when exceeding the set
value. (pre-setting value is 030)
Function (20) Alarm mode:
(0) shows “ON”, (1) shows “OFF”. (pre-setting figure is 000) Once set at “ OFF “ , alarm
will not function.
Queuing for door
shutting time input.
DOOR SENSOR SEC
( 1 - 255 ) : 030 256
DOOR SENSOR SEC
( 1 - 255 ) : 030 015
DOOR SENSOR SEC
( 1 - 255 ) : 030 _ _ _
Key in 19
Key in
#
or
*
Esc system function selection.
Key in the #or *
Go into function 19.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.
Queuing for alarm
mode input.
ALARM MODE
( 0 / ON , 1 / OFF ) : 2
ALARM MODE
( 0 / ON , 1 / OFF ) : 0
ALARM MODE
( 0 / ON , 1 / OFF ) : 1
Key in 20
Key in #or *
Esc system function selection.
Key in the #or *
Go into function 20.
SYSTEM FUNCTIONS
SELECTION : _ _
status light on, display
function selection.
Key in
#system password#
Go into system function setup.
Setting successfully,
beep sound occurred.
Wrong input, beep
sound on continuously.
back to system function selection.