SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
T B M
700 PILOTS INFORMATION MANUAL
Back to
Contents
Page 3.4.5
Rev. 6
3.3 AIR START
AIR START WITHOUT STARTER
(STARTER ASSIST NOT MANDATORY) (Contd)
9 –”IGNITION switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10 Condition lever LO / IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 ITT and Ng MONITOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 When Ng ~ 50 % steady IGNITION AUTO or OFF. . . . . . . . . . . .
13 Condition lever HI / IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 Propeller governor lever MAX. RPM. . . . . . . . . . . . . . . . . . . . . . . . .
15 Power lever AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 Electrical equipment AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . .
17 –”AUX BP fuel selector AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 –”BLEED VALVE switch AS REQUIRED. . . . . . . . . . . . . . . . . . . . .