T B M
PILOTS INFORMATION MANUAL 700
SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
Back to
Contents
Page 3.4.4
Rev. 2
3.3 AIR START
AIR START WITHOUT STARTER
(STARTER ASSIST NOT MANDATORY)
CAUTION
THE STARTER CANNOT OPERATE IF THE GENERATOR
SELECTOR IS ON STBY
CAUTION
IGNITION IS NOT AVAILABLE IF THE ESS BUS TIE SWITCH IS
KEPT EMER
1 –”BLEED VALVE switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAUTION
BLEED VALVE SWITCH ON MAY CAUSE
OVERTEMPERATURE OR ABNORMAL ACCELERATION
2 –”FREON switch (if installed) OFF. . . . . . . . . . . . . . . . . . . . . . . . . . .
3 Air start envelope CHECKED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Speedwith propeller windmilling 140 < IAS< 190 KIAS
with feathered propeller IAS > 190 KIAS
4 Electrical consumption REDUCE. . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Power lever IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 Condition lever CUT OFF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7 Tank selector CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 –”AUX BP fuel switch ON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .