Page 3.4.3
Rev. 6
3.3 AIR START
AIR START WITH STARTER (Contd)
12 Condition lever LO / IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
when Ng ~ 13 %
13 ITT and Ng MONITOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 When Ng ~ 50 % steady STARTER OFF. . . . . . . . . . . . . . . . . . . .
IGNITION AUTO or OFF
15 Condition lever HI / IDLE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16 Propeller governor lever MAX. RPM. . . . . . . . . . . . . . . . . . . . . . . . .
17 Power lever AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18 Electrical equipment AS REQUIRED. . . . . . . . . . . . . . . . . . . . . . . .
19 –”AUX BP fuel switch AUTO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20 –”BLEED VALVE switch AS REQUIRED. . . . . . . . . . . . . . . . . . . . .
CAUTION
WITH THE EFS 40 OPTION, DISPLAYS ARE LOST
MOMENTARILY DURING STARTER OPERATION