SECTION 3
EMERGENCY PROCEDURES
D.G.A.C. Approved
T B M
700 PILOT’S INFORMATION MANUAL
Back to
Contents
Page 3.10.5
Rev. 6
3.10 – PRESSURIZATION AND AIR CONDITIONING
AMBER WARNING LIGHT
VACUUM LO
ON
Suction gage indicator CHECK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low vacuum may lead to misfunctioning of leading edge
deicing, pressurization and gyroscopic vacuum–operated
instruments MONITOR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
If necessary, fly to an altitude ≤ 12000 ft and if possible return to VMC
conditions