3.12 DEICING SYSTEM
LEADING EDGES DEICING FAILURE
Symptoms : Failure on one of the two pneumatic deicing pulses :
Ice on wing outboard sections
Or ice on wing inboard sections and stabilizers
One of the two cycling green lights is not lit
1 LEAVE icing conditions as soon as possible
2 –”AIRFRAME DE ICE switch OFF. . . . . . . . . . . . . . . . . . . . . . . . . . .
PROPELLER DEICING FAILURE
Symptoms : Propeller deicing green light is not lit
Propeller vibrations
1 REDUCE power
2 ACTUATE propeller governor lever to vary RPM within operating
range
3 LEAVE icing conditions as soon as possible